THE SYSTEM FOR AUTOMATED ELECTRIC METER READING - BASIC APPLICATION
VSS ORD APP®
The System for automated electric meter reading (VSS ORD APP®) represents basic model of the overall System and is used for contactless reading of electricity consumption and control of technical accuracy of meters using smart phones.
VSS ORD APP® provides:
Recording accurate data on consumption of the meter
Photo of meter with electricity consumption
Automatic reading of consumption via OCR Engine
Possibility of controlling manual data entry on consumption
Automatic GPS position as evidence that reader has read the concrete meter
Automatic (exact) time of meter reading
Recording and control of the validity of distribution seals
Registering and alarming of magnet presence near meter
Recording all technical characteristics of meters on the field
Entering remarks that are present on the field
Technical photos of meter – recording technical shortcomings
Logic control of data entry on consumption
Automatic internet download of meter reading lists to smart phone
Automatic internet transfer of data consumption to server of System
Keeping records about working on field and efficiency of readers
Creating and updating meter reading lists
Control of all meters in every monthly reading before sending data to Billing System of Electric Distribution Companies
Keeping record of any updates or changes on data consumption on meters
Control of operation and effective determination of abuse in recording consumption on meters, etc.
VSS ORD APP® Systems operate with following subsystem:
The System for automated identification of electricity theft by magnets – VSS ORD Magnet APP® - as default subsystem that is integrated in basic version of application
The System for routing and monitoring work of readers in the field – GPS VSS ORD® - as default subsystem that is integrated in basic version of application
The System for security control of meters using electronic RFID seals - VSS ORD RFID Seal® - as add-on subsystem that can be included as upgrade for basic model of the System
The System for automated meter reading with IR probes – VSS ORD IR APP®- as add-on subsystem that can be included as upgrade for basic model of the System
The System for electronic invoicing and payment of electricity bills on the field - VSS ORD mBilling System®- as add-on subsystem that can be included as upgrade for basic model of the System
Software for identifying and locating loses in low voltage (LV) network – VSS ORD ANTI-LOST APP®- as add-on subsystem that can be included as upgrade for basic model of the System
Main benefits of VSS ORD APP® System in reading process of meters are as follows:
Reduces the number of meter readers which reduces operating costs up to 30% in reading process
Reduces commercial and technical losses in distribution of electricity from 30% up to 50%, through following mechanisms
Eliminates manual data entry on electricity consumption in the Billing System by overwriting data from paper reading sheets, which significantly reduces the need for manpower, but also prevents errors of data entry (retyping)
For each meter read there is a photo that shows consumption of the meter, with "embossing" these data on photos of meter which thus become unique and authentic, and dramatically eliminates the existence of any consumer’s complaints, recording non-existent consumption (abuse)
For each meter read there is the exact time and GPS position of reading, therefore in this way we eliminate the possibility of tuning data of electricity consumption for consumers in the field
There is an automated System for recording all possible situations (anomalies on meters and meters points, as well as in the process of meter reading) in the field, presenting the right image of reading, as well as recording the real situation on the field and electricity consumption of consumers
System for writing a ‘’0’’ consumption of non-read meters is disabled which was one of the main reasons for “fixing" the consumption of certain users
System for writing non-existent (reduced) consumption to specific consumers is disabled, because there are photos for each meter reading
There is a System for automatic recording of abuse by placing a magnet on a meter
Consumption control of meters is carried out on total number of meters for every reading, and not on much smaller sample (up to 20% of the meters – by sending inspector on the field). In that way, data that are delivered to the Billing System for printing bills are very accurate and credible. Therefore, we receive the right image of condition and technical correctness of measuring points on the field
Number of workers in control and their involvement is reduced to a shorter period
System for proper management of database is introduced: type, model, year and manufacturer of meters; keeping accurate record on installation date of seals on meters; keeping proper record of control accuracy and calibration of meters, etc.
Percentage of read meters increases up to over 95 %!